i-scan OE Technology

The i-scan OE function incorporates a new technology of combining bandwidth-limiting light with digital image processing. PENTAX Medical’s original optical enhancement (i-scan OE) filters that produce bandwidth-limiting light, combined with image enhancement processing technology, enable the display of the surface structures of the blood vessels, glandular ducts and mucosal membranes in higher contrasts than white light. This combination has the potential to help physicians improve characterization and increase detection and diagnosis of gastrointestinal lesions even more precisely.

The innovative optical filters achieve higher overall transmittance by connecting the peaks of the hemoglobin absorption spectrum (415 nm, 540 nm and 570 nm) creating a continuous wavelength spectrum. There are two modes with different OE filters (Mode 1 and Mode 2).

 

 

Mode 1

 

The optical filter used in this mode has a feature that enhances the contrast of blood vessels. There are two large absorption bands around 415 nm and around 540 nm in the absorption wavelength of hemoglobin. The surface of the mucous membrane and internal blood vessel can be easily identified by constructing an image with light that has a wavelength of around 415nm suitable for emphasizing blood vessels on the surface of the mucous membrane and light with a wavelength of around 540 nm suitable for emphasizing blood vessels inside the mucous membrane.

Mode 1

 

Mode 2

 

The filter used in this mode transmits long-wavelength light (red) as well as light that has the characteristics suitable for high-lighting blood vessels as mentioned in the section about Mode 1 (lights with wavelengths around 415 nm and around 540nm). A combination of these 3 lights allows a highlighting effect, which can be obtained in Mode 1 and the creation of images close to natural, white-light images.

Mode 2

Mode 1 is designed mainly to improve visualization of microvessels with a sufficient amount of light, and Mode 2 is designed to improve contrast of white-light observation by bringing the color tone of the overall image closer to that of natural color (white color tone) with much more light than that of the Mode 1 filter. By using the optical filter (Mode 1 or Mode 2), the microvascular patterns in addition to microsurface patterns on the mucosal surface are clearly observed, which means that the knowledge obtained by optical chromoendoscopy could potentially be brought into the i-scan technology. According to recent publications by using OE Mode 2 and Mode 1, it was found that these methods may be useful for detection and characterization of gastrointestinal neoplasms, respectively.1

 

1Neumann et al. Present and future perspectives of virtual chromoendoscopy with i-scan and optical enhancement technology. Digestive Endoscopy 2013; 26 doi: 10.1111/den.12190

 


Downloads

A unique combination of optical and digital enhancements, for improved in vivo diagnosis

A unique combination of optical and digital enhancements, for improved in vivo diagnosis

A leap forward for in vivo histology with i-scan and i-scan OE, a unique combination of digital and optical enhancements

Download PDF

i-scan, technology with proven results

i-scan, technology with proven results

A novel endoscopic classification system using i-scan improves dysplasia detection in Barrett’s oesophagus

Download PDF

i-scan Atlas for Gastroenterology

i-scan Atlas for Gastroenterology

Gastrointestinal endoscopy with HD+, i-scan and i-scan OE.i-scan and i-scan OE, a unique combination of digital and optical enhancements to support the clinical pathway.

Download PDF

Gaining a complete picture of the GI tract through new image enhancement technology

Gaining a complete picture of the GI tract through new image enhancement technology

i-scan real-time image processing technology has proven to be a clinically-effective digital image enhanced endoscopy (IEE) technique, using virtual chromoendoscopy to provide superior visualization of vascular and tissue architecture on the mucosal surface. Now a new optical enhancement option using band-limited light has been added to the i-scan menu.

Download PDF